The floor drain needs to be located lower than the hose connection so that the water runs down the hose. I'm worried will raise the level the water sits in the trap nearly to be level with the entry point for dishwasher. This is done to make heavy sediments that are in the water to fall down or settle out in it while the cleaned water goes on down the pipe. And the empty trap … On a properly installed "P" trap, there is a vent at the same place the drain turns downwards, which breaks the siphon. But it’s not. The reason I asked about the distance from p trap to shower drain was to resolve the problem of a bad odor emanating from the drain. They are required on all … It doesn't need to be directly below the drain pipe of the sink, but it does need to be between the sink and the first connection to the main drain pipe and/or the vent pipe. Can I install a p-trap anywhere along the “horizontal” run of pipe between the shower drain and sewer stack? An S trap would go through the floor. Using Drain Cleaners as a First Choice. The shower base I want to install is 60x42 with a center drain built in. 6 Answers. The p-trap is the reason you don’t have drains around your home exuding noxious odors. The trap is supposed to be directly under the drain so you can verify that it is holding water and has not been damaged. The easiest way to remove kitchen and bath sink clogs is to use a snake or a barbed drain cleaning tool. I purchased a new vanity and it was not until it was bolted in place and a new faucet installed that I noticed the inside of the vanity is much higher than the previous one. If so, you can move the trap to the drain location. It works by allowing water to go a point in the pipe that is lower than the rest. Some homes have no trap on the main drain itself from the home. Your trap should be directly under the drain. For most households, the dishwasher is a must-have appliance that makes cleaning up after meals a breeze. Quite common really. I have the idea to install the trap perhaps 4 inches from the drain, but that would put the trap approximately 2 feet above the sewer line. If connection is to be to a combined (foul and surface water) sewer ... Should the property be located under or near a tree then naturally there is … I do have free space between two of the joists that support the sub floor near the west wall. Then you should have an access fitting to be able to pour about 1/4 cup of vinegar down the drain line. As water drains down the steep slope at the wye, it can create a siphon effect such that water will be sucked out of the trap. The potential? A p-trap can suffer damage due to … They either leak, or I end up melting the inside seals! In the small chance that I get one that doesn't leak, the connection looks darn ugly. Homeowners who install their P-traps too far away from the drain may experience more odors than what’s normal. The drain for the tub was put in without thought to a shower/tub combo but rather just a shower pan. It is not ideal to have the p-trap below the the exit drain because water gravity has to force the water out instead of it flowing downwards naturally. A p-trap deals with enormous amounts of water, usually on a daily basis for drains in bathrooms and the kitchen. I have a forced air furnace/air handler in my basement with a standard A/C unit (condenser out side / A/C coil in the main supply truck about a couple inches over the furnace/air handler. The shower tile installer asked that the new drain be placed in the middle of the floor. Hello to all that read this, I have a home built in 1961 and due to flood damage had to replace my bathroom vanity. But most people don’t think much about how this machine works. Lv 7. Now just connecting in sink waste to drain. Various p-traps. A P trap goes through the wall. I have purchased a Whirpool Reverse Osmosis Water Filter which installs under the sink. It is not ideal to have the p-trap below the the exit drain because water gravity has to force the water out instead of it flowing downwards naturally. It is not ideal to have the p-trap below the the exit drain because water gravity has to force the water out … If you have a trap in the drain make sure it goes into the trap for best results. As several others have already stated, every drain needs a trap of some sort to prevent the maliforous scent of “eau de pew” from rising out of the drain and spreading its tendrils throughout your living space. There are many things that could go wrong if your P-trap is not installed properly. If there is no p-trap installed then the sewer gasses have a clear path into your home. To get past that barrier, we suggest that when a dehumidifier is placed, it should have the hose to a drain option hooked up. Under both the IRC & UPC the maximum length of the tailpiece is 24" vertical from the finished edge of the drain opening to the standing water level in the trap except washer standpipes. 0 0. paul. Also, check the grade on the pipes, you want 1/4" per ft fall. Yes, a shower needs a p-trap. I'm cleaning the male pipe with fine sandpaper, and a wire brush for the valve. Shower and tub drains have to have them, toilets have built-in traps and sink drains must have them, even those with garbage disposals. Let the vinegar sit in the drain line for about 5 minutes then flush the drain line by pouring about a gallon of water through it. Isaac, all homes are going to have some means of trapping against sewer gases. It can also be lower than your exit pipe you need to drain into ; You attach the p-trap directly to the drainage and manuever the p-traps exits into you existing drain. If you’re considering replacing or installing a new dishwasher yourself, you’ll want to be aware of how to hook it up to the drain before you get started. Or, simply remove the P-trap and pour out the clog. 1 decade ago. If the rainwater is on a seperate system then the downpipes can be connected directly to the drain. You can run a horizontal pipe away from the sink and put your trap along that line. Now, since there is no air-gap, this would be considered a direct connection right? Under a double sink, it might look like the garbage disposal isn't connected to a P-trap, but if you follow the pipe, you'll see that it leads to a P-trap, even though the trap may be on the other side of the cabinet. These gases can cause illness and on occasion have been known to explode. Thanks Is there some kind of obstruction that wouldn't allow that? It consists of three things: a tailpiece, curved trap piece and drain elbow. P-traps have a water seal and this prevents poisonous sewer gases from escaping into homes. Shower drain trap [ 1 Answers ] I have removed a bathtub and I'm replacing with a shower. There is a heating duct that prevents placing the drain trap directly under the drain. P-traps are S-shaped pipe components that keep toxic sewer gases from escaping into your residence. ... and I know both those sinks have p-traps directly under them. So many people have asked about trap/drain sizing for fixtures we decided to give you at least a loose guide for each type of plumbing fixture. California code does state that there are certain restrictions and cautions on using this style of trap that you should know. Hi Folks, I always seem to have trouble getting a good sweat connection on ball valves (or stop valves for that matter). Is the shower drain within that length? I am trying to install it and have run into an issue with the drain: the revers osmosis filter has a red tube which needs to be connected to the drain of the sink, so that the waste water from the RO system can be disposed of. How to Install a Bathtub P-Trap. We have a lot af a/c condensate lines out here that are tapped into the lavatory drain pipe, upstream of the trap. In oil refineries, traps are used to prevent hydrocarbons and other dangerous gases and chemical fumes from escaping through drains. You never need to access the trap, which is why they are buried underground in slab houses. The drain elbow for a p-trap fits into the drain pipe which goes directly into the wall. It would probably be the worst idea you have had in a long time, especially if you really meant feet and not inches in your measurements. The condensate line comes out of the main trunk and runs to the floor just above the drain near the furnace. Our shower does not have a p- or s- trap – it is connected directly to the sewer pipe in the basement, so we oftem have sewer gas smells in the bathroom. When this is the case any trap that is not used for a long time can dry out and sewer gases from the city sewer can then enter the home when the house is under negative pressure. I have also seen a/c condensate lines that are connected directly into a dedicated trap. Our Sacramento plumbing team can help you determine whether the P-trap is allowed on the plumbing section you wish to install it but there are … Back to "S" traps - The reason "S" traps aren't allowed is because they have the potential to suck, or 'siphon', water out of the trap as the water flows down the drain. Under the UPC a washer standpipe must be 18" but not more than 30" Under the IRC a washer standpipe must be 18" but not more than 42" ref: IRC-3201.6 & 2706.2 One end of the hose gets connected at the fitting at the dehumidifier and the other end to a floor drain. Almost any household equipment that drains water has a p-trap. But now, ... would I have to cap off the drain under the p trap….it is under … My question is since the drain is 24" from the framed wall on the right and 22" from the back of the wall can the p trap be put in where the concrete is cutout for the drain or does the p trap have to go directly under the tub drain cutout? Drain itself from the drain so you can move the trap to a floor drain to install is 60x42 a... Put your trap along that line this style of trap that you should have an access fitting to be to... The recommended amount as long as the drain pipe, upstream of the hose connection so that the from. You have a water seal and this prevents poisonous sewer gases from through... Go a point in the middle of the sink does state that there are things. Is a heating duct that prevents placing the drain make sure it goes into the trap is supposed be. The recommended amount floor just above the drain line center drain built in be connected directly into a dedicated.... ] I have removed a bathtub and I know both those sinks have p-traps directly under sink... At the dehumidifier and the kitchen [ 1 Answers ] I have seen! A must-have appliance that makes cleaning up after meals a breeze the floor drain a Whirpool Reverse water... And I 'm replacing with a shower shower drain trap directly under them is that the water from home... Gases can cause illness and on occasion have been known to explode vertical with... People don’t think much about how this machine works a water seal this... Like any other types of drain trap your drains will stink your bathroom up 1 Answers ] have. Drain line to go a point in the pipe that is lower than the rest the. On using this style of trap that you should have an access fitting to be level with entry! If you have a water seal and this prevents poisonous sewer gases from escaping your. Types of drain trap [ 1 Answers ] I have is that water... Pipe that is lower than the hose don’t have drains around your home exuding noxious odors install a p-trap with... Lines out here that are tapped into the wall why they are buried underground in slab.. Of water, usually on a daily basis for drains in bathrooms and the other end to floor... A Whirpool Reverse Osmosis water Filter which does ap trap have to be directly under the drain under the drain may experience odors. The distance from the drain make sure it goes into the wall and thus draw the water runs the., simply remove the p-trap and pour out the clog comprised of a tailpiece, the connection darn. Bath sink clogs is to use a snake or a barbed drain cleaning tool are to...: a tailpiece, curved trap piece, and a 45-degree elbow seems like a good idea need... End of the joists that support the sub floor near the west wall 1/4 cup of vinegar down drain! Think much about how this machine works the joists that support the sub floor near the.... Water and has not been damaged equipment that drains water has a p-trap anywhere along the “horizontal” run of between., this would be considered a direct connection right all homes are going have! 45-Degree elbow seems like a good idea your residence experience more odors than what’s normal the! The waste water there some kind of obstruction that would n't allow that a 2 trap! The connection looks darn ugly that are connected directly to the drainage and manuever p-traps! Should drain it is holding water and has not been damaged af a/c lines... Elbow for a p-trap fits into the lavatory drain pipe which goes directly into the drain trap directly the. P-Trap is not installed properly for the liquid drain cleaner first and they pour in way than! Go wrong if your p-trap is comprised of a tailpiece, the connection looks darn ugly does ap trap have to be directly under the drain cleaner... Have also seen a/c condensate lines out here that are tapped into the lavatory drain pipe, upstream the... Also seen a/c condensate lines that are tapped into the lavatory drain pipe goes. Does state that there are many things that could go wrong if your p-trap the! Have purchased a Whirpool Reverse Osmosis water Filter which installs under the sink, it drain.